7 Call Sensing

Now I have power I can start to building the first component of the exchange - call sense control. I add in the the 3w 1k resistor that will feed power to the four lines. When a handset is lifted the line is energized and so will operate the quad ILQ74 optocoupler that will eventually fit into the 16 pin socket. Below the socket are the diodes, the 1w 1k resistors and 10k pull-up resistors for each line that will operate the optocoupler. Also present is the 4 way socket that will hold the Panasonic AQW210EH solid state dual relay  the will switch out the call sense lines once a handset is lifted. The other relay will be used to "bridge" the source and destination phones between the radial capacitor when a call is connected. 


The lesson to learn here is always check the data sheet as I made a mistake in the wiring feeding the optocoupler. From the picture above I have the feed going from top to bottom, in on pin 1, out on 2, in on 3, out on 4 and so on. In reality the feed goes...

1 - In

2 - Out

3 - Out

4 - In 

5. In ... etc

So I have to un-pick my soldering and re-wire it correctly. The other slightly annoying thing is now the call sense line numbers won't run 1 to 4 so I make a mental note of this when I come to connect the optocoupler outputs. I also note I have fitted the pullup resistors in the wrong place and move them accordingly, after the 1W 1K resistors.


Just to add insult to injury when I connect the supply it seems I have accidentally created a dead short which blows the LM317. 


The short is through an un-cut link on a track, the is VR replaced and all is good. I get the right voltages in the right places when testing with a voltmeter. A good start. In the second picture, I used a Dupont connector to short over where the relay will eventually go so I can get power to the call sense circuitry.